Roof Guides
Guides on roofing topics for Calgary homes, newest first.

Attic Ventilation in Calgary: The 1 in 300 Rule, Intake vs Exhaust and How Many Vents a Roof Needs
How the 1 in 300 attic ventilation rule works, with a worked example: an 1,800 sq ft ceiling needs 864 sq in of net free area, half intake, half exhaust.
Read the guide
Hail Damage on a Calgary Roof: How to Identify It, What Insurers Look For and What Is Not Hail
How to tell hail bruising from normal granule loss on asphalt shingles, why marks can take several months to show, and why hail claims go to insurance.
Read the guide
What a Calgary Roof Replacement Quote Should Include: The Complete Shingle Roof System, Layer by Layer
The ten layers a Calgary shingle roof quote should name, with the standard behind each, and why Owens Corning's 3-of-5 rule sets the warranty tier.
Read the guide